Deutsches Ozeanographisches
Datenzentrum Inventur der Elisabeth Mann Borgese-Reise 06EZ1206a (DOD-Ref-No.20120275)
Inventory of Elisabeth Mann Borgese Cruise 06EZ1206a (DOD-Ref-No.20120275)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
Elisabeth Mann Borgese 06EZ1206a 03.05.2012 - 12.05.2012 BLMP+
 
Baltic Sea  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Nausch Gunther Leibniz-Institut fur Ostseeforschung, Warnemunde Rostock Rostock Karte
Map
 

Ziel der Reise / Objectives of Cruise:

Studies of the spatial and temporal variations of hydrographic, hydrochemical and hydrobiological parameters in the frame of the COMBINE Programme of HELCOM as well as measurements for the IOW's long term data set

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
IOW Wasmund Norbert 11 stations B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
chlorophyll determination, other pigments yes
IOW Nausch Gunther 11 stations B06
Dissolved organic matter (e.g. DOC)
TOC-analyzer yes
IOW Wasmund Norbert 14 stations B08
Phytoplankton
net sample, full sample, different depths yes
IOW Wasmund Norbert 14 stations B09
Zooplankton
plankton net, mesh size 100?m yes
IOW Nausch Gunther 11 stations B71
Particulate organic matter (e.g. POC, PON)
CHN-analyzer yes
IOW Nausch Gunther 62 stations H00
Stations
- no
IOW Feistel Rainer 62 stations H09
Water bottle stations
Rosette sampler no
IOW Feistel Rainer 99 stations H10
CTD-Stations
CTD casts + sensors for oxygen, sound, fluorescence and turbidity yes
IOW Nausch Gunther 62 stations H21
Oxygen
oxygen, Winkler method, potentiometric titration yes
IOW Nausch Gunther 46 stations H22
Phosphates
colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 6 stations H23
Total - P
persulphate oxidation followed by phosphate determination yes
IOW Nausch Gunther 46 stations H24
Nitrates
colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 46 stations H25
Nitrites
colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 46 stations H26
Silicates
colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 9 stations H33
Other dissolved gases
hydrogen sulphide (colorimetric method) no
IOW Nausch Gunther 6 stations H75
Total-N
persulphate oxidation followed by nitrate determination yes
IOW Nausch Gunther 11 stations H76
Ammonia
colorimetric standard method (manual) yes
IOW Nausch Gunther 1 n miles H80
Other physical measurements
Underway measurements during the whole trip such as coordinates, depth, meteorological parameter and so on yes
14.9.2024