Deutsches Ozeanographisches
Datenzentrum
Inventur der Bios-Reise Bios23042005 (DOD-Ref-No.20051032)
Inventory of Bios Cruise Bios23042005 (DOD-Ref-No.20051032)
Plattform Platform |
Reise-Nr. Cruise-No. |
Zeitraum Period |
Projekt Project |
Arbeitsgebiet Working area |
---|---|---|---|---|
Bios | Bios23042005 | 23.04.2005 - 23.04.2005 |
Fahrtleiter Chief Scientist | Institut Institute | Auslaufhafen Port of departure | Einlaufhafen Port of return | Stationskarte Station map | Schiffsroute Trackchart |
---|---|---|---|---|---|
Kuspilic Grozdan | Institute of Oceanography and Fisheries | Split | Split |
Ziel der Reise / Objectives of Cruise:
-
Messungen / Measurements
Institut Institute |
Wissenschaftler Scientist |
Anzahl Number |
Einheit Unit |
Typ der Messungen Type of measurements |
Kommentar Comments |
Daten im DOD Data in DOD |
---|---|---|---|---|---|---|
IORS | Marasovic Ivona | 7 | stations | B02 Phytoplankton pigments (e.g. chlorophyll, fluorescence) |
Chlorophyl a (florimetric), | no |
IORS | Krstulovic Nada | 6 | stations | B07 Pelagic bacteria / micro-organisms |
Bacterial number, | no |
IORS | Marasovic Ivona | 7 | stations | B08 Phytoplankton |
UTHERMOHL method of identification and calculating of phytoplankton (Utermohl,1958), | no |
IORS | Bojanic Natalia | 6 | stations | B09 Zooplankton |
"Niskin" bottle sampling (microzooplankton), | no |
IORS | Bogner Danijela | 2 | stations | G02 Grab |
Van Veen Grab (Windaus Labortechnik)-Granulometric composition,Sieving and hydrometric method according to Casagrande | no |
IORS | Bogner Danijela | 2 | stations | G02 Grab |
Van Veen Grab (Windaus-Labortechnik)-Total nitrogen, Organic carbon,Sanples were analysed on CHNS-O analyzer | no |
IORS | Matijevic Slavica | 2 | stations | G04 Core-soft bottom (no. of cores) |
Corer (25mm)-Redoxpotential, Voltametric deermination of sediment redox-potential | no |
IORS | Grbec Branka | 11 | stations | H10 CTD-Stations |
CTD SBE 25 S.N. 2529343-0340(s), Temperature; S.N. 4295; 8/24/02; 7/1/04, Conductivity; S.N. 2753; 8/16/02; 7/23/04, Pressure, Strain Gauge; S.N. 0505; 8/27/02; 6/25/04 | no |
IORS | Morovic Mira | 11 | stations | H16 Transparency (e.g. transmissometer) |
Sechi disc (white, 30cm), White sechi disk, 30cm | no |
IORS | Kuspilic Grozdan | 6 | stations | H21 Oxygen |
Winkler titration, Oxygen is determined at standard oceanographic depths. By the Winkler method oxygen isexpressed as ml/L. If temperature and salinity is known, oxygen saturation can be calculated. | no |
IORS | Kuspilic Grozdan | 6 | stations | H22 Phosphates |
Nutrient (phosphates), Working equipment: AutoAnalyzer Bran+Luebbe AA3 , Following the method of Murphy and Riley, this automated procedure for the determination of orthophosphate is based on the colorimetric method in which a blue color is formed by the reaction of orthophosphate, molybdate ion and antimony ion followed by the reduction with ascorbic acid at an ph<1. | no |
IORS | Kuspilic Grozdan | 6 | stations | H24 Nitrates |
Nutrient (nitrates),Working equipment: AutoAnalyzer Bran+Luebbe AA3,This automated procedure for the determination of nitrate uses the procedure whereby nitrate is reduced to nitrite by a copper-cadmium reductor column. The nitrite then reacts with sulfanilamide under acidic conditions to form a diazo compound. This compound then couples with N-1-naphthylethylenediamine dihydrochloride to form a purple azo dye. | no |
IORS | Kuspilic Grozdan | 6 | stations | H25 Nitrites |
Nutrient (nitrites), Working equipment: AutoAnalyzer Bran+Luebbe AA3,This automated procedure for the determination of nitrite uses the procedure whereby the nitrite ion reacts with sulfanilamide under acidic conditions to form a diazo compound. This compound then couples with N-1-naphthylethylenediamine dihydrochloride to form a reddish-purple azo dye. | no |
IORS | Kuspilic Grozdan | 6 | stations | H26 Silicates |
Nutrient (silicates),Working equipment: AutoAnalyzer Bran+Luebbe AA3,This automated procedure for the determination of soluble silicates is based on the reduction of silico-molybdate in acidic solution to molybdenum blue by ascorbic acid. Oxalic acid is introduced to the sample stream before the addition of ascorbic acid to minimize interference from phosphates. | no |
IORS | Kuspilic Grozdan | 6 | stations | H75 Total-N |
Nutrients (total - N),Working equipment: AutoAnalyzer Bran+Luebbe AA3,After oxidation of water sample in the UV oxidation unit, the sample has been analysed by the same procedure described as nitrogen analysis. | no |
IORS | Kuspilic Grozdan | 6 | stations | H76 Ammonia |
Nutrient (ammonia),Working equipment: AutoAnalyzer Bran+Luebbe AA3, This method uses the Berthelot reaction, in which a blue-green coloured complex is formed. A complexing agent is used to prevent the precipitation of calcium and magnesium hydroxsides. Sodium nitroprusside is used to enhance the sensitivity. | no |