Deutsches Ozeanographisches
Datenzentrum Inventur der Gauss-Reise 446B (DOD-Ref-No.20050165)
Inventory of Gauss Cruise 446B (DOD-Ref-No.20050165)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
Gauss 446B 29.08.2005 - 05.09.2005 BLMP+
 
German Bight  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Weigelt-Krenz Sieglinde Bundesamt fuer Seeschifffahrt und Hydrographie Cuxhaven Bremerhaven Karte
Map
 

Ziel der Reise / Objectives of Cruise:

A)Removal of water-, suspended matter and sediment samples for analysis of anorganic compounds, nutrients, chlorophyll and artificial radioactivity B) Analysis of oxygen content and pH measurement; Secchi-disc (under water light level) C)At all stations CTD-measurements (fluorescence, turbidity, temperature and salinity)

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
BSH Weigelt-Krenz Sieglinde 84 samples B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
Analysis onboard with 1 HZ fluorimeter no
BSH Schmolke Stefan 2 cores G04
Core-soft bottom (no. of cores)
- yes
BSH Weigelt-Krenz Sieglinde 38 stations H00
Stations
- yes
BSH Becker G. 36 stations H10
CTD-Stations
CTD measurement at every station; water samples are taken with the Rosette water sampler which is equipped with Niskin tumblers yes
BSH Weichert Hans-Joachim - n miles H11
Sub-surface measurements underway (T, S)
- yes
BSH Weigelt-Krenz Sieglinde 36 stations H17
Optics (e.g. underwater light levels)
Measurement of the underwater light levels with Secchi-Disc no
BSH Weigelt-Krenz Sieglinde 84 samples H21
Oxygen
- yes
BSH Weigelt-Krenz Sieglinde 420 samples H22
Phosphates
- yes
BSH Weigelt-Krenz Sieglinde 168 samples H23
Total - P
- yes
BSH Weigelt-Krenz Sieglinde 420 samples H24
Nitrates
- yes
BSH Weigelt-Krenz Sieglinde 420 samples H25
Nitrites
- yes
BSH Weigelt-Krenz Sieglinde 420 samples H26
Silicates
- yes
BSH Weigelt-Krenz Sieglinde 36 samples H28
PH
Water samples from the Niskin tumblers are taken and determined no
BSH Schmolke Stefan 35 stations H30
Trace elements
- yes
BSH Nies Hartmut 146 samples H31
Radioactivity
Water samples are taken ( per 100 l or 70 l) to analyse later no
BSH Weigelt-Krenz Sieglinde 168 samples H75
Total-N
- yes
BSH Weigelt-Krenz Sieglinde 420 samples H76
Ammonia
- yes
BSH Schmolke Stefan 35 stations P01
Suspended matter
- yes
BSH Schmolke Stefan 8 samples P02
Trace metals
Sediment samples from the box corer yes
BSH Schmolke Stefan 35 stations P02
Trace metals
Suspended matter yes
BSH Theobald N. 31 samples P04
Chlorinated hydrocarbons
Determination of organic compounds with liquid-liquid extraction to analyse later yes
BSH Theobald N. 34 samples P05
Other dissolved substances
Determination of polar pesticides with solid phase extraction to analyse later yes
13.4.2024