Deutsches Ozeanographisches
Datenzentrum
Inventur der Bios-Reise Bios09072004 (DOD-Ref-No.20041421)
Inventory of Bios Cruise Bios09072004 (DOD-Ref-No.20041421)
Plattform Platform |
Reise-Nr. Cruise-No. |
Zeitraum Period |
Projekt Project |
Arbeitsgebiet Working area |
---|---|---|---|---|
Bios | Bios09072004 | 09.07.2004 - 20.07.2004 | VIRK SMALL PROD. VELA BOROVICA |
Adriatic Sea |
Fahrtleiter Chief Scientist | Institut Institute | Auslaufhafen Port of departure | Einlaufhafen Port of return | Stationskarte Station map | Schiffsroute Trackchart |
---|---|---|---|---|---|
Stojanoski Lambe | Institute of Oceanography and Fisheries | Split | Split |
Ziel der Reise / Objectives of Cruise:
-
Messungen / Measurements
Institut Institute |
Wissenschaftler Scientist |
Anzahl Number |
Einheit Unit |
Typ der Messungen Type of measurements |
Kommentar Comments |
Daten im DOD Data in DOD |
---|---|---|---|---|---|---|
IORS | Bojanic Natalia | 2 | stations | B09 Zooplankton |
Net sampling (mesozooplankton) 125 micrometers, Nansen net, mesh net 125 micrometers | no |
IORS | Bojanic Natalia | 7 | stations | B09 Zooplankton |
"Niskin" bottle sampling (microzooplankton), | no |
IORS | Grbec Branka | 12 | stations | H10 CTD-Stations |
CTD SBE 25S.N.:2528482-0339 (b), Temperature; S.N. 4198; 9/17/02, Conductivity; S.N. 2797; 9/6/02, Pressure, Strain Gauge; S.N. 0502; 7/31/02, Oxygen, SBE 43; S.N. 0296; 9/18/02, Fluorometer, Wetlab ECO-AFL; S.N. 042; 9/25/02 , Transmissometer, Chelsea/Seatech/Wetlab Cstar; S.N. CST-544PR; 8/7/02, PAR/Irradiance, Biospherical/Licor; S.N. 3216; 7/23/02 | no |
IORS | Morovic Mira | 29 | stations | H10 CTD-Stations |
CTD SBE 25S.N.:2528482-0339 (b), Temperature; S.N. 4198; 9/17/02, Conductivity; S.N. 2797; 9/6/02, Pressure, Strain Gauge; S.N. 0502; 7/31/02, Oxygen, SBE 43; S.N. 0296; 9/18/02, Fluorometer, Wetlab ECO-AFL; S.N. 042; 9/25/02 , Transmissometer, Chelsea/Seatech/Wetlab Cstar; S.N. CST-544PR; 8/7/02, PAR/Irradiance, Biospherical/Licor; S.N. 3216; 7/23/02 | no |
IORS | Morovic Mira | 1 | stations | H16 Transparency (e.g. transmissometer) |
Sechi disc (white, 30cm), White sechi disk, 30cm | no |
IORS | Kuspilic Grozdan | 29 | stations | H21 Oxygen |
Winkler titration, Oxygen is determined at standard oceanographic depths. By the Winkler method oxygen isexpressed as ml/L. If temperature and salinity is known, oxygen saturation can be calculated. | no |
IORS | Kuspilic Grozdan | 29 | stations | H22 Phosphates |
Nutrient (phosphates), Working equipment: AutoAnalyzer Bran Luebbe AA3 , Following the method of Murphy and Riley, this automated procedure for the determination of orthophosphate is based on the colorimetric method in which a blue color is formed by the reaction of orthophosphate, molybdate ion and antimony ion followed by the reduction with ascorbic acid at an ph<1. | no |
IORS | Kuspilic Grozdan | 29 | stations | H23 Total - P |
Nutrients (total - P),Working equipment: AutoAnalyzer Bran Luebbe AA3,After oxidation of water sample in the UV oxidation unit, the sample has been analysed by the same procedure described as phosphorusly analysis. | no |
IORS | Kuspilic Grozdan | 29 | stations | H24 Nitrates |
Nutrient (nitrates),Working equipment: AutoAnalyzer Bran Luebbe AA3,This automated procedure for the determination of nitrate uses the procedure whereby nitrate is reduced to nitrite by a copper-cadmium reductor column. The nitrite then reacts with sulfanilamide under acidic conditions to form a diazo compound. This compound then couples with N-1-naphthylethylenediamine dihydrochloride to form a p | no |
IORS | Kuspilic Grozdan | 29 | stations | H25 Nitrites |
Nutrient (nitrites), Working equipment: AutoAnalyzer Bran Luebbe AA3,This automated procedure for the determination of nitrite uses the procedure whereby the nitrite ion reacts with sulfanilamide under acidic conditions to form a diazo compound. This compound then couples with N-1-naphthylethylenediamine dihydrochloride to form a reddish-purple azo dye. | no |
IORS | Kuspilic Grozdan | 29 | stations | H26 Silicates |
Nutrient (silicates),Working equipment: AutoAnalyzer Bran Luebbe AA3,This automated procedure for the determination of soluble silicates is based on the reduction of silico-molybdate in acidic solution to molybdenum blue by ascorbic acid. Oxalic acid is introduced to the sample stream before the addition of ascorbic acid to minimize interference from phosphates. | no |
IORS | Kuspilic Grozdan | 20 | stations | H28 PH |
pH meter,Measuring of pH value is based on potential difference between reference and working electrode (glass electrodes). | no |
IORS | Kuspilic Grozdan | 29 | stations | H75 Total-N |
Nutrients (total - N),Working equipment: AutoAnalyzer Bran Luebbe AA3,After oxidation of water sample in the UV oxidation unit, the sample has been analysed by the same procedure described as nitrogen analysis. | no |
IORS | Kuspilic Grozdan | 29 | stations | H76 Ammonia |
Nutrient (ammonia),Working equipment: AutoAnalyzer Bran Luebbe AA3, This method uses the Berthelot reaction, in which a blue-green coloured complex is formed. A complexing agent is used to prevent the precipitation of calcium and magnesium hydroxsides. Sodium nitroprusside is used to enhance the sensitivity. | no |
IORS | Grbec Branka | 9 | stations | M06 Routine standard measurements |
Air presure senzor, | no |
IORS | Grbec Branka | 9 | stations | M06 Routine standard measurements |
Wet/dry termometer, Wet/dry termometer; Lambreht, S.N. 62176.0004 | no |
IORS | Grbec Branka | 9 | stations | M06 Routine standard measurements |
anemometer, S.N. | no |
IORS | Morovic Mira | 20 | stations | M06 Routine standard measurements |
anemometer, S.N. | no |
IORS | Kljakovic Gaspic Zorana | 5 | stations | P02 Trace metals |
Atomic absorption spectrometry, Atomic absorption spectrophotometer PE1100B | no |
Verankerungen / Moorings
Institut Institute |
Wissenschaftler Scientist |
Typ der Messungen Type of measurements |
Kommentar Comments |
geogr.Breite Latitude |
geogr.Länge Longitude |
Daten im DOD Data in DOD |
---|---|---|---|---|---|---|
IORS | Dadic Valdo | D09 | Sea bird 26-03, Tide gauge deployment ,interval: 15 min. | 43° 30.0' N | 16° 9.0' E | no |
IORS | Dadic Valdo | D71 | RDI Workhorse Sentinel 300, ,interval: 10 min. Two stations on positions 43? 30.2 N 16? 9.4 E and 43? 30.3 N 16? 9.5 E | 43° 30.0' N | 16° 9.0' E | no |
IORS | Dadic Valdo | D72 | Sea bird 26-03, Wave gauge deployment ,interval: 15 min. | 43° 30.0' N | 16° 9.0' E | no |