Deutsches Ozeanographisches
Datenzentrum
Inventur der Prof. A. Penck-Reise 04-11 (DOD-Ref-No.20040137)
Inventory of Prof. A. Penck Cruise 04-11 (DOD-Ref-No.20040137)
Plattform Platform |
Reise-Nr. Cruise-No. |
Zeitraum Period |
Projekt Project |
Arbeitsgebiet Working area |
---|---|---|---|---|
Prof. A. Penck | 04-11 | 30.04.2004 - 10.05.2004 | BLMP+ COMBINE |
Baltic Sea |
Fahrtleiter Chief Scientist | Institut Institute | Auslaufhafen Port of departure | Einlaufhafen Port of return | Stationskarte Station map | Schiffsroute Trackchart |
---|---|---|---|---|---|
Nausch Gunther | Leibniz-Institut fur Ostseeforschung, Warnemunde | Warnemunde | Warnemunde | Karte Map |
Ziel der Reise / Objectives of Cruise:
Studies of the spatial and temporal variations of hydrodynamic, hydrochemical and hydrobiological parmeters in the frame of the COMBINE Programme of HELCOM
Messungen / Measurements
Institut Institute |
Wissenschaftler Scientist |
Anzahl Number |
Einheit Unit |
Typ der Messungen Type of measurements |
Kommentar Comments |
Daten im DOD Data in DOD |
---|---|---|---|---|---|---|
IOW | Wasmund Norbert | 20 | stations | B02 Phytoplankton pigments (e.g. chlorophyll, fluorescence) |
Chlorphyll determination, other pigments | yes |
IOW | Nausch Gunther | 17 | stations | B06 Dissolved organic matter (e.g. DOC) |
TOC-analyzer | no |
IOW | Wasmund Norbert | 13 | stations | B08 Phytoplankton |
Net sample, full sample, different depth | yes |
IOW | Wasmund Norbert | 14 | stations | B09 Zooplankton |
Plankton net, mesh size 100 ?m | yes |
IOW | Nausch Gunther | 17 | stations | B71 Particulate organic matter (e.g. POC, PON) |
CHN-analyzer | no |
IOW | Nausch Gunther | 84 | stations | H00 Stations |
- | no |
IOW | Feistel Rainer | 79 | stations | H09 Water bottle stations |
Rosette sampler | yes |
IOW | Feistel Rainer | 81 | stations | H10 CTD-Stations |
CTD -casts + sensor for oxygen, sound, fluorescence and turbidity | yes |
IOW | Nausch Gunther | 79 | stations | H21 Oxygen |
Winkler method, potentiometric tritration | yes |
IOW | Nausch Gunther | 46 | stations | H22 Phosphates |
Colorimetric standard method (autoanalyzer) | yes |
IOW | Nausch Gunther | 18 | stations | H23 Total - P |
Persulphate oxidation followed by phosphate determination | yes |
IOW | Nausch Gunther | 46 | stations | H24 Nitrates |
Colorimetric standard method (autoanalyzer) | yes |
IOW | Nausch Gunther | 46 | stations | H25 Nitrites |
Colorimetric standard method (autoanalyzer) | yes |
IOW | Nausch Gunther | 46 | stations | H26 Silicates |
Colorimetric standard method (autoanalyzer) | yes |
BSH | Herrmann J. | 4 | stations | H31 Radioactivity |
- | yes |
IOW | Nausch Gunther | 4 | stations | H33 Other dissolved gases |
Hydrogen sulphide (colrimetric method) | yes |
IOW | Nausch Gunther | 18 | stations | H75 Total-N |
Persulphate oxidation followed by nitrate determination | yes |
IOW | Nausch Gunther | 17 | stations | H76 Ammonia |
Colorimetric standard method (manual) | yes |