Deutsches Ozeanographisches
Datenzentrum Inventur der Prof. A. Penck-Reise 04-11 (DOD-Ref-No.20040137)
Inventory of Prof. A. Penck Cruise 04-11 (DOD-Ref-No.20040137)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
Prof. A. Penck 04-11 30.04.2004 - 10.05.2004 BLMP+
COMBINE
 
Baltic Sea  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Nausch Gunther Leibniz-Institut fur Ostseeforschung, Warnemunde Warnemunde Warnemunde Karte
Map
 

Ziel der Reise / Objectives of Cruise:

Studies of the spatial and temporal variations of hydrodynamic, hydrochemical and hydrobiological parmeters in the frame of the COMBINE Programme of HELCOM

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
IOW Wasmund Norbert 20 stations B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
Chlorphyll determination, other pigments yes
IOW Nausch Gunther 17 stations B06
Dissolved organic matter (e.g. DOC)
TOC-analyzer no
IOW Wasmund Norbert 13 stations B08
Phytoplankton
Net sample, full sample, different depth yes
IOW Wasmund Norbert 14 stations B09
Zooplankton
Plankton net, mesh size 100 ?m yes
IOW Nausch Gunther 17 stations B71
Particulate organic matter (e.g. POC, PON)
CHN-analyzer no
IOW Nausch Gunther 84 stations H00
Stations
- no
IOW Feistel Rainer 79 stations H09
Water bottle stations
Rosette sampler yes
IOW Feistel Rainer 81 stations H10
CTD-Stations
CTD -casts + sensor for oxygen, sound, fluorescence and turbidity yes
IOW Nausch Gunther 79 stations H21
Oxygen
Winkler method, potentiometric tritration yes
IOW Nausch Gunther 46 stations H22
Phosphates
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 18 stations H23
Total - P
Persulphate oxidation followed by phosphate determination yes
IOW Nausch Gunther 46 stations H24
Nitrates
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 46 stations H25
Nitrites
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 46 stations H26
Silicates
Colorimetric standard method (autoanalyzer) yes
BSH Herrmann J. 4 stations H31
Radioactivity
- yes
IOW Nausch Gunther 4 stations H33
Other dissolved gases
Hydrogen sulphide (colrimetric method) yes
IOW Nausch Gunther 18 stations H75
Total-N
Persulphate oxidation followed by nitrate determination yes
IOW Nausch Gunther 17 stations H76
Ammonia
Colorimetric standard method (manual) yes